Add to Cart
IEC 60065 Test Probe D 1mm Diameter 100mm Length for HAZARDOUS LIVE TEST
IEC60065 Clause 9.1 .4 TERMINALS
The use of a single-pole plug or a bare wire to make connection with a contact of a TERMINAL for earth or antenna or for audio, video or associated signals, shall not involve the risk of an electric shock.
The test is not applied to TERMINALS marked with the symbol of 5.3 b). Test Finger Probe
NOTE See also 1 5.1 .2.
Compliance is checked by the following tests:
Within 25 mm measured from each contact of the TERMINAL , a test pin according to IEC 61032:1997, test probe D, however limited in length to 20 mm ± 0,2 mm, is applied in every possible position, in case of doubt with a force of 10 N ± 1 N.
Each contact is tested with a straight test probe according to IEC 61032:1997, test probe D, in case of doubt with a force of 1 N ± 0,1 N.
The test probes shall not become HAZARDOUS LIVE Test Finger Probe
Standard:IEC61032 figure 4 and IEC60529 for IP4 and IEC60065.
Application:This rod probe is intended to verify the protection of persons against access to hazardous parts. It is also used to verify the protection against access with a wire.
Test sample:Easily accessible enclosure live parts or mechanical parts. Test Finger Probe
Feature:It can be used for anti-electric shock test when equipped with amphenol connector. Or used for enclosure protection test when open threaded hole of M6 at the end of the handle (connected with pull and push dynamometer) .The probe whose model number is with "T" is with force. Test Finger Probe
Parameters:
Model | HT-I04 |
Name | Test rod probe D |
Diameter of the metal wire | Ф1+0.05 |
Sphere diameter | SФ35±0.2 |
Handle diameter | Ф10 |
Probe length | 100±0.2 |
Handle length | 100 |
Force | ---- |
Applied standard | IEC61032.1 |