Guangzhou HongCe Equipment Co., Ltd.

We provide you with industry leading test equipment, advanced online system and solutions–anywhere in the world.

Manufacturer from China
Verified Supplier
12 Years
Home / Products / Test Finger Probe /

UL507 Fig 9.2 Articulate Probe With Web Stop Test Finger Probe For Accessibility Of Live Parts

Contact Now
Guangzhou HongCe Equipment Co., Ltd.
Visit Website
City:guangzhou
Province/State:guangdong
Country/Region:china
Contact Person:MsTessa Huang
Contact Now

UL507 Fig 9.2 Articulate Probe With Web Stop Test Finger Probe For Accessibility Of Live Parts

Ask Latest Price
Video Channel
Brand Name :HongCe
Model Number :HT-U01
Certification :calibration certificate(cost additional)
Place of Origin :China
MOQ :1 set
Price :Negotiatable
Payment Terms :T/T
Supply Ability :100 set/ month
Delivery Time :7 Days
Packaging Details :Aluminum Box
Standard :UL474 Fig 5.1, UL507 Fig 9.2(PA100A), IEC62368 Fig V1 and etc.
Feature :Nylon handle + probe
Material :Stainless steel
Product name :UL Accessibility Probe
Warranty :1 Year
Application :Accessibility of Live Parts
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

UL507 Fig 9.2 Articulate Probe With Web Stop Test Finger Probe for Accessibility of Live Parts

Description in UL507 Clause 9.1~9.3:

9 Accessibility of Live Parts
9.1 General
9.1.1 To reduce the risk of unintentional contact that involves a risk of electric shock from uninsulated live parts and film-coated wire, an opening in an enclosure of an appliance or in a motor shall comply with 9.3.1 – 9.4.1 and Table 9.1.
9.2 Directly- and indirectly-accessible motor
9.2.1 A directly accessible motor is a motor:
a) That can be contacted without removing any part; or
b) That is located to be accessible to contact.
9.3 Application of probes
9.3.1 The probes referenced in Table 9.1 and illustrated in Figure 9.2 shall be applied to any depth that the opening permits and shall be rotated or angled before, during, and after insertion through the opening to any position that is necessary to try to contact an uninsulated live part or film-coated wire. If necessary, the configuration shall be changed after insertion through the opening. Configuration refers to positioning of the jointed portions of the probes.

Standard:IEC62368 Fig V1, UL474 Fig 5.1, UL507 Fig 9.2(PA100A), UL982 Fig 7.1, UL1017 Fig 2, UL1062 Fig1.2, UL1278Fig 8.3, UL1310 Fig 16.2, UL6500 Fig14, UL60065 Fig14 and UL60950 Fig NAF.1.

Application:It is widely used in the enclosure protection test of the electrical equipment.

Test sample:Easily accessible enclosure live parts or mechanical parts.

Feature:Nylon handle + probe, it is manufactured according to the standard figure.

Parameter:

Name parameter
1 R3.5
2 0.05
3 0.05
4 0.05
5 0.05
6 16
7 25.4
8 0.05
9 50
10 78
11 R25
12 78
13 97
14 Approx. 30°
15 5.8
16 15
17 19
18 21.5
19 25.4
20 5
21 30
22 60
23 90
24 96
25 100
26 136
27 154
28 234

UL507 Fig 9.2 Articulate Probe With Web Stop Test Finger Probe For Accessibility Of Live Parts

Picture for reference:

UL507 Fig 9.2 Articulate Probe With Web Stop Test Finger Probe For Accessibility Of Live Parts

Inquiry Cart 0