Add to Cart
Flammability Testing Equipment Horizontal Vertical Flame Tester for Fire Hazard Testing
Standard:
UL94 Test for Flammability of Plastic Materials for Parts in Devices and Appliances;
IEC 60695-11-2 Fire hazard testing - Part 1 1 -2: Test f1 ames - 1 kW nominal pre-mixed flame - Apparatus , confirmatory test arrangement and guidance;
IEC 60695-11-3 Fire hazard testing – Part 11-3: Test flames – 500 W flames – Apparatus and confirmational test methods;
IEC 60695-11-4 Fire hazard testing – Part 11-4: Test flames – 50 W flame – Apparatus and confirmational test method;
Application:
This device is for Safety for Test for Flammability of Plastic Materials for Parts in Devices and Appliances and also for testing electrotechnical products with regard to fire hazard.
Feature:
The product chamber is irony spray, and configured a transparent viewing window, the PLC control the test start and stop, and shows the burning time, afterflame time, afterglow time. This device is easy to use and has reliable performance.
Test sample:
Appliance and plastic materials parts of electrical equipment. Flammability Testing Equipment
Parameters:
Parameters Model | HVF-3(Touch screen) |
Working voltage | 220V/50Hz |
Power/grade | 50W and 500W double power switching |
Control operation mode | PLC control, 7 inch color touch screen operation, with infrared remote control |
Blast burner standard | IEC60695-11-3/IEC60695-11-4/10,UL94, inner diameter:Φ9.5±0.3mm,length:100mm, made of brass |
Gas pressure | 0.1MPa |
Gas flow | 50W:105±5ml/min or 18±1mm; 500W: 965±30ml/min or 117±3 mm, flow meter adjustment |
U type pressure gauge back pressure water column height | 50W:10mm; 500W:125±5 mm |
©©©Test angle | 50W: 0°,45°; 500W: 20° |
Burning time | 0-9999X0.1S , adjustable |
Burning times | 0-9999 times, adjustable. Flammability Testing Equipment |
Residual flame/Residual glow | 0-9999X0.1S , can be displayed |
Test flame calibration | Temperature measuring copper head:50W:Ф5.5mm±0.01mm,weight before drilling 1.76 ± 0 .01 g;500W:Ф9mm±0.01mm,weight before drilling 10 ± 0 .05g |
Thermocouple: The American original Omega φ0.5 armour nickel-chromium/nickel aluminum wire K-Thermocouple, temperature resistance 1100° | |
Distance between the bunsen burner port to temperature measuring copper block:50W: 10±1 mm; 500W: 55±1 mm | |
Flame height: 50W: 20±2mm(there is no internal and external flame); 500W: Inner flame:40±2mm, Outer flame:125±10mm | |
Temperature rise time from100±2°to 700°±3°50W: 44±2S; 500W: 54±2S | |
Lighting | Equip with lighting in the test chamber, with control |
Test chamber and dimension | > 0.75 cube, black inwall, with exhaust fan, dimension:1100*550*1200mm, 140kg |