Guangzhou HongCe Equipment Co., Ltd.

We provide you with industry leading test equipment, advanced online system and solutions–anywhere in the world.

Manufacturer from China
Verified Supplier
12 Years
Home / Products / IEC Test Equipment /

ISO16358 Household Air Conditioner Enthalpy Difference Room Psychrometric Testing Laboratory

Contact Now
Guangzhou HongCe Equipment Co., Ltd.
Visit Website
City:guangzhou
Province/State:guangdong
Country/Region:china
Contact Person:MsTessa Huang
Contact Now

ISO16358 Household Air Conditioner Enthalpy Difference Room Psychrometric Testing Laboratory

Ask Latest Price
Video Channel
Brand Name :HongCe
Model Number :HCN001
Certification :Third Party Calibration (Cost Additional)
Place of Origin :China
MOQ :1 set
Price :Customized
Payment Terms :T/T
Supply Ability :1 Set / Month
Delivery Time :2 Months
Packaging Details :Plywood
UUT Type :Household Air Conditioner
Test Method :Air Enthalpy
Overall Dimensions :10000×4000×3400 mm
Indoor Dimensions :5500×4000×3400 mm
Outdoor Dimensions :4500×4000×3400 mm
Standard :ISO5151, EN14852, ISO16358
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

Air Enthalpy Difference Testing Room for Household Air Conditioner

The chamber design is based on Air enthalpy difference method, use for air conditioner and heat pump combination property testing, it can test the cooling and heating capacity, power consumption, EER, COP, SEER and many performance parameters for test unit. The chamber often use for product development and quality control department, it is necessary facility at manufacturer and certification organization.

The chamber combine outdoor room, indoor room, air condition systems(include cooling, heating and humidify system), air flow measurement systems, electrical controlling systems, computer systems, etc.

The chamber design base on relative international test standard or some local standard, such as ISO5151,EN14852,GB/T7724, we also can customizate according the customer’s special test standard.

Test Unit Capacity Range:

RANGE TYPE

Air Flow Rate (m3/h)

Cooling&Heating Capacity (W) m3/h
Air-conditioner 180~2,000

Cooling Capacity: 1500~10,000W

Heating Capacity: 1500~11,000W

——

Air cooling type

Air cooler

180~2,000

Cooling Capacity: 1500~10,000W

Heating Capacity: 1500~11,000W

——

Multisplit system

Air-conditioner

NO NO

Chamber Extenal Size Details ( Not include the operation room and location for coolers and humidifiers )

Chamber Extenal Size:10000×4000×3200 mm (Lengh×Width×Height)

Indoor Extenal Size:5500×4000×3200 mm (Lengh×Width×Height)

Outdoor Extenal Size:4500×4000×3200 mm (Lengh×Width×Height)

Chamber Ambient Temperature and Humidity Testing Accuracy and Control Accuracy

Indoor Temperature 5~45℃ Testing Accuracy ±0.1℃ Control Accuracy ±0.2℃
Humidity 30~90%RH Testing Accuracy ±0.1℃(WB) Control Accuracy ±0.2℃(WB)
Oudoor Temperature -15~60℃ Testing Accuracy ±0.1℃ Control Accuracy ±0.2℃
Humidity 30~90% Testing Accuracy ±0.1℃(WB) Control Accuracy ±0.2℃(WB)

Software Interface:

ISO16358 Household Air Conditioner Enthalpy Difference Room Psychrometric Testing Laboratory

Inquiry Cart 0