Guangzhou HongCe Equipment Co., Ltd.

We provide you with industry leading test equipment, advanced online system and solutions–anywhere in the world.

Manufacturer from China
Verified Supplier
11 Years
Home / Products / Light Testing Equipment /

IEC 60598-1 Clause 8.15 Arrangement Light Testing Equipment For Impact Test

Contact Now
Guangzhou HongCe Equipment Co., Ltd.
Visit Website
City:guangzhou
Province/State:guangdong
Country/Region:china
Contact Person:MsTessa Huang
Contact Now

IEC 60598-1 Clause 8.15 Arrangement Light Testing Equipment For Impact Test

Ask Latest Price
Video Channel
Brand Name :HongCe
Model Number :HL-1
Certification :Calibration Certificate(cost additional)
Place of Origin :China
MOQ :1 set
Payment Terms :T/T, PayPal, D/A, Western Union, MoneyGram, L/C
Supply Ability :10 Sets per month
Delivery Time :25 days
Packaging Details :Standard export packing
Price :Negotiatable
Steel jaws width :15mm
Steel jaws radius :2.5 mm
Applied force :100 N
Standard :IEC 60598-1 clause 8.15
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

IEC 60598-1 Clause 8.15 Arrangement For Impact Test For Handlamps

Product information:

This test device is designed and manufactured according to the standard requirements of IEC 60598-1 clause 8.15.1 for handlamps having a handle or shell of flexible material, such as rubber or polychloroprene, compliance shall be checked by the following test.

The parts of the handlamp which are gripped in normal use, are subjected to a pressure test in an apparatus similar to that shown in figure 3, the test being made in a heating cabinet maintained at a temperature of 100±2℃.

The sample is clamped between steel jaws, having a cylindrical face of 25 mm radius, a width of 15 mm and a length of 50 mm. The corners are rounded with a radius of 2.5 mm.

The sample is clamped in such a way that the jaws press against it in the area where it is gripped in normal use, the centre line of the jaws coinciding as nearly as possible with the centre of this area.

The force applied through the jaws is 100 N.

After 1 h, the jaws are removed and the sample shall show no damage.

Technical parameters:

Steel jaws width 15mm
Steel jaws radius 2.5 mm
The force applied through the jaws 100 N
Standard IEC 60598-1 clause 8.15

IEC 60598-1 Clause 8.15 Arrangement Light Testing Equipment For Impact Test