Guangzhou HongCe Equipment Co., Ltd.

We provide you with industry leading test equipment, advanced online system and solutions–anywhere in the world.

Manufacturer from China
Verified Supplier
12 Years
Home / Products / Electrical Appliance Tester /

IEC60598 Clause 11.2 Electrical Appliance Tester Clearances Creepage Distances And Solid Insulation

Contact Now
Guangzhou HongCe Equipment Co., Ltd.
Visit Website
City:guangzhou
Province/State:guangdong
Country/Region:china
Contact Person:MsTessa Huang
Contact Now

IEC60598 Clause 11.2 Electrical Appliance Tester Clearances Creepage Distances And Solid Insulation

Ask Latest Price
Video Channel
Brand Name :HongCe
Model Number :CK-4
Certification :TUV、ITS、CSA、BV、SGS 、CNAS(cost additional)
Place of Origin :China
MOQ :1 set
Payment Terms :T/T
Supply Ability :100 set/ month
Delivery Time :7 Days
Packaging Details :Aluminum Box
Price :Negotiatable
Material :Stainless steel
Creepage distances gauges :23
Standard to :IEC60884-1, IEC60598, and IEC60335 etc.
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

IEC60598 Clause 11.2 Electrical Appliance Tester Clearances Creepage Distances And Solid Insulation

Product information:

The test gauges is conforms to IEC60884-1, IEC60598,IEC60335 etc., it is used to determine the shortest path between two conductive parts, or between a conductive part and the bounding surface of the equipment, measured along the surface of the insulation, with specifications made according to the requirements.

The creepage distances gauges is with 23 creepage distance gauges:

1.0mm/1.2mm/1.4mm/1.5mm/1.6mm/2.0mm/2.4mm/2.5mm/2.8mm/3.0mm/3.2mm/3.3mm/3.5mm/4.0mm/4.5mm/5.0mm/5.5mm/6.0mm/6.3mm/6.4mm/6.5mm/7.0mm/8.0mm

Material: Stainless steel

Parts detailed in the table of Annex M shall be adequately spaced. Creepage distances and clearances shall be not less than the values given in Tables 11.1 and 11.2.

Values for creepage distances and clearances may be found for intermediate values of working voltages by linear interpolation between tabulated values. No values are specified for working voltages below 25 V as the test voltage of Table 10.2 is considered sufficient.

Distances between current-carrying parts of opposite polarity shall comply with the

requirements for basic insulation.

11.2.1 Compliance is checked by measurements made with and without conductors of the largest section connected to the terminals of the luminaires.

The contribution to the creepage distance of any groove less than 1 mm wide is limited to its width.

Any air gap less than 1 mm wide is ignored in calculating the total clearance, unless the total clearance is less than 3 mm where one third of the air gap width shall be taken into account.

For luminaires provided with an appliance inlet, the measurements are made with an appropriate connector inserted.

Distances through slots or openings in external parts of insulating material are measured with metal foil in contact with the accessible surface. The foil is pushed into corners and similar places by means of the standard test finger specified in IEC 60529, but it is not pressed into openings.

Internal creepage distances in permanently sealed components are not measured. Examples of permanently sealed components are components sealed-off or compound filled.

The values in Table 11.1 do not apply to components for which separate IEC publications exist, but do apply to mounting and accessibility distances to the component when it is incorporated in the luminaire.

Creepage distances at a supply terminal shall be measured from the live part in the terminal to any accessible metal parts, and the clearance shall be measured between incoming supply wiring and accessible metal parts, i.e. from a bare conductor of the largest section to the metal parts which can be accessible. At the internal wiring side of the terminal, the clearance shall be measured between live parts of the terminal and accessible metal parts (see Figure 24).

NOTE The measurements of the clearances from supply and from internal wiring differ because the luminaire manufacturer does not have control over the length of insulation removed from the supply wiring by the installer.

When creepage distances and clearances are determined at bushings, cord anchorages, wire carriers or clips, the measurement shall be made with the cable fitted.

IEC60598 Clause 11.2 Electrical Appliance Tester Clearances Creepage Distances And Solid Insulation

Inquiry Cart 0